.. _lbl-dldb_damage_FEMA_P58_2nd_B_10_31 *********************** B.10.31 - Steel Columns *********************** The following models are available: .. raw:: html

B.10.31.001 | Bolted shear tab gravity connections

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.001.html .. raw:: html
.. raw:: html

B.10.31.011a | Steel Column Base Plates, Column W < 150 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.011a.html .. raw:: html
.. raw:: html

B.10.31.011b | Steel Column Base Plates, Column 150 plf < W < 300 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.011b.html .. raw:: html
.. raw:: html

B.10.31.011c | Steel Column Base Plates, Column W > 300 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.011c.html .. raw:: html
.. raw:: html

B.10.31.021a | Welded column splices, Column W < 150 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Notes: Fracture is not expected where weld has adequate toughness and the maximum weld root stress is below 1.5Fu from column P/A+M/S under story drift using A and S from weld root area. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.021a.html .. raw:: html
.. raw:: html

B.10.31.021b | Welded column splices, Column 150 plf < W < 300 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Notes: Fracture is not expected where weld has adequate toughness and the maximum weld root stress is below 1.5Fu from column P/A+M/S under story drift using A and S from weld root area. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.021b.html .. raw:: html
.. raw:: html

B.10.31.021c | Welded column splices, Column W > 300 plf

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. | Notes: Fracture is not expected where weld has adequate toughness and the maximum weld root stress is below 1.5Fu from column P/A+M/S under story drift using A and S from weld root area. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.31.021c.html .. raw:: html