.. _lbl-dldb_damage_FEMA_P58_2nd_B_10_35 *************************** B.10.35 - Steel Connections *************************** The following models are available: .. raw:: html

B.10.35.001 | Post-Northridge RBS connection with welded web, beam one side of column only, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.001.html .. raw:: html
.. raw:: html

B.10.35.002 | Post-Northridge RBS connection with welded web, beam one side of column only, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.002.html .. raw:: html
.. raw:: html

B.10.35.011 | Post-Northridge RBS connection with welded web, beams both sides of column, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.011.html .. raw:: html
.. raw:: html

B.10.35.012 | Post-Northridge RBS connection with welded web, beams both sides of column, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.012.html .. raw:: html
.. raw:: html

B.10.35.021 | Post-Northridge welded steel moment connection other than RBS, beam one side, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.021.html .. raw:: html
.. raw:: html

B.10.35.022 | Post-Northridge welded steel moment connection other than RBS, beam one side, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.022.html .. raw:: html
.. raw:: html

B.10.35.031 | Post-Northridge welded steel moment connection other than RBS, beams both sides, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.031.html .. raw:: html
.. raw:: html

B.10.35.032 | Post-Northridge welded steel moment connection other than RBS, beams both sides, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.032.html .. raw:: html
.. raw:: html

B.10.35.041 | Pre-Northridge WUF-B beam-column joint, beam one side of column, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.041.html .. raw:: html
.. raw:: html

B.10.35.042 | Pre-Northridge WUF-B beam-column joint, beam one side of column, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.042.html .. raw:: html
.. raw:: html

B.10.35.051 | Pre-Northridge WUF-B beam-column joint, beam both sides of column, beam depth <= W27

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.051.html .. raw:: html
.. raw:: html

B.10.35.052 | Pre-Northridge WUF-B beam-column joint, beam both sides of column, beam depth >= W30

| Costing is on a per bay basis. Costing does not include fireproofing removal or reapplication cost. | Author: Greg Deierlein Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.052.html .. raw:: html
.. raw:: html

B.10.35.061a | EBF Shear Link, no floor beams, link w < 100 PLF

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.061a.html .. raw:: html
.. raw:: html

B.10.35.061b | EBF Shear Link, no floor beams, link w < 200 PLF

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.061b.html .. raw:: html
.. raw:: html

B.10.35.062a | EBF Shear Link, with floor beams, link w < 100 PLF

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.062a.html .. raw:: html
.. raw:: html

B.10.35.062b | EBF Shear Link, with floor beams, link w < 200 PLF

| Costing is on a per connection basis. Costing does not include fireproofing removal or reapplication cost. Suggested Block Size: 1 EA (round up to integer quantity) .. raw:: html :file: B.10.35.062b.html .. raw:: html