.. _lbl-dldb_damage_FEMA_P58_2nd_D_20_21 ************************************************** D.20.21 - Domestic Water Distribution - Cold Water ************************************************** The following models are available: .. raw:: html

D.20.21.011a | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.011a.html .. raw:: html
.. raw:: html

D.20.21.011b | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.011b.html .. raw:: html
.. raw:: html

D.20.21.012a | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC C, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC C | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.012a.html .. raw:: html
.. raw:: html

D.20.21.012b | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC C, BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC C | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.012b.html .. raw:: html
.. raw:: html

D.20.21.013a | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.013a.html .. raw:: html
.. raw:: html

D.20.21.013b | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F, BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.013b.html .. raw:: html
.. raw:: html

D.20.21.014a | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F (OSHPD or sim), PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Special Regulation (e.g. OSHPD) for piping installations | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.014a.html .. raw:: html
.. raw:: html

D.20.21.014b | Cold or Hot Potable - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F (OSHPD or sim), BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Special Regulation (e.g. OSHPD) for piping installations | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.014b.html .. raw:: html
.. raw:: html

D.20.21.021a | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC A or B, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.021a.html .. raw:: html
.. raw:: html

D.20.21.022a | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC C, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC C | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.022a.html .. raw:: html
.. raw:: html

D.20.21.023a | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC D,E,F, PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.023a.html .. raw:: html
.. raw:: html

D.20.21.023b | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC D,E,F, BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.023b.html .. raw:: html
.. raw:: html

D.20.21.024a | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC D,E,F (OSPHD or sim), PIPING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Special Regulation (e.g. OSHPD) for piping installations | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.024a.html .. raw:: html
.. raw:: html

D.20.21.024b | Cold or Hot Potable Water Piping (dia > 2.5 inches), SDC D,E,F (OSPHD or sim), BRACING FRAGILITY

| Potable water. Costing based upon 1000 ft segments. | Construction Quality: Special Regulation (e.g. OSHPD) for piping installations | Seismic Installation Conditions: SDC D, E or F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.21.024b.html .. raw:: html