.. _lbl-dldb_damage_FEMA_P58_2nd_D_20_22 ************************************************* D.20.22 - Domestic Water Distribution - Hot Water ************************************************* The following models are available: .. raw:: html

D.20.22.011a | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B (no seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.011a.html .. raw:: html
.. raw:: html

D.20.22.011b | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC A or B, BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B (no seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.011b.html .. raw:: html
.. raw:: html

D.20.22.012a | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC C, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC C (low seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.012a.html .. raw:: html
.. raw:: html

D.20.22.012b | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC C, BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC C (low seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.012b.html .. raw:: html
.. raw:: html

D.20.22.013a | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.013a.html .. raw:: html
.. raw:: html

D.20.22.013b | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F, BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.013b.html .. raw:: html
.. raw:: html

D.20.22.014a | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F (OSHPD or sim), PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Special Regulations (e.g. OSHPD) for Piping Installations | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.014a.html .. raw:: html
.. raw:: html

D.20.22.014b | Heating hot Water Piping - Small Diameter Threaded Steel - (2.5 inches in diameter or less), SDC D, E, or F (OSHPD or sim), BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Special Regulations (e.g. OSHPD) for Piping Installations | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.014b.html .. raw:: html
.. raw:: html

D.20.22.021a | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC A or B, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC A or B (no seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.021a.html .. raw:: html
.. raw:: html

D.20.22.022a | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC C, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC C (low seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.022a.html .. raw:: html
.. raw:: html

D.20.22.023a | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC D, E, or F, PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E, F (high seismic design | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.023a.html .. raw:: html
.. raw:: html

D.20.22.023b | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC D, E, or F, BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Normal | Seismic Installation Conditions: SDC D, E, F (high seismic design | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.023b.html .. raw:: html
.. raw:: html

D.20.22.024a | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC D, E, or F (OSHPD or sim), PIPING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Special Regulation (e.g. OSHPD) for Piping Installations | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.024a.html .. raw:: html
.. raw:: html

D.20.22.024b | Heating hot Water Piping - Large Diameter Welded Steel - (greater than 2.5 inches in diameter), SDC D, E, or F (OSHPD or sim), BRACING FRAGILITY

| Heating water. Costing based upon 1000 ft segments of pipe, pipe 2.5 inches in diameter or less | Construction Quality: Special Regulation (e.g. OSHPD) for Piping Installations | Seismic Installation Conditions: SDC D, E, F (high seismic design) | Notes: Consequence is for piping only. Enter floor wetting consequence seperately. Cost includes allowance for MEP relocation to perform work. Suggested Block Size: 1000 LF .. raw:: html :file: D.20.22.024b.html .. raw:: html