.. _lbl-dldb_damage_FEMA_P58_2nd_C_20_11 **************************** C.20.11 - Stair Construction **************************** The following models are available: .. raw:: html

C.20.11.001a | Prefabricated steel stair with steel treads and landings with seismic joints that accommodate drift.

| Flexible stair with seismic interstory slip joint. Steel prefab stringers, steel or concrete filled pan treads. | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.001a-Carbon.html **Cost** .. raw:: html :file: C.20.11.001a-Cost.html **Energy** .. raw:: html :file: C.20.11.001a-Energy.html **Time** .. raw:: html :file: C.20.11.001a-Time.html .. raw:: html
.. raw:: html

C.20.11.001b | Prefabricated steel stair with steel treads and landings with no seismic joint.

| Flexible stair without seismic interstory slip joint. Steel prefab stringers, steel or concrete filled pan treads. | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: Confirm median demand and dispersion values Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.001b-Carbon.html **Cost** .. raw:: html :file: C.20.11.001b-Cost.html **Energy** .. raw:: html :file: C.20.11.001b-Energy.html **Time** .. raw:: html :file: C.20.11.001b-Time.html .. raw:: html
.. raw:: html

C.20.11.011a | Non-monolithic precast concrete stair assembly with concrete stringers and treads with seismic joints that accommodate drift.

| Rigid stair with seismic interstory drift joint. Precast concrete stair. | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.011a-Carbon.html **Cost** .. raw:: html :file: C.20.11.011a-Cost.html **Energy** .. raw:: html :file: C.20.11.011a-Energy.html **Time** .. raw:: html :file: C.20.11.011a-Time.html .. raw:: html
.. raw:: html

C.20.11.011b | Non-monolithic precast concrete stair assembly with concrete stringers and treads with no seismic joint.

| Rigid stair without seismic interstory drift joint. Precast concrete stair. | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: Confirm median demand and dispersion values. Base document noted that there was insufficient data to establish median demand or dispersion values. The median demand and dispersion values listed are from a best fit approximation of the data performed by MKA. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.011b-Carbon.html **Cost** .. raw:: html :file: C.20.11.011b-Cost.html **Energy** .. raw:: html :file: C.20.11.011b-Energy.html **Time** .. raw:: html :file: C.20.11.011b-Time.html .. raw:: html
.. raw:: html

C.20.11.021a | Monolithic cast-in-place and precast concrete stairs with seismic joints that accommodate drift - replace in kind if replacement is required.

| Cast in place concrete stair, with seismic interstory drift joint | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.021a-Carbon.html **Cost** .. raw:: html :file: C.20.11.021a-Cost.html **Energy** .. raw:: html :file: C.20.11.021a-Energy.html **Time** .. raw:: html :file: C.20.11.021a-Time.html .. raw:: html
.. raw:: html

C.20.11.021b | Monolithic cast-in-place and precast concrete stairs with no seismic joints - replace in kind if replacement is required.

| Cast in place concrete stair, no seismic interstory drift joint | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.021b-Carbon.html **Cost** .. raw:: html :file: C.20.11.021b-Cost.html **Energy** .. raw:: html :file: C.20.11.021b-Energy.html **Time** .. raw:: html :file: C.20.11.021b-Time.html .. raw:: html
.. raw:: html

C.20.11.021c | Monolithic cast-in-place and precast concrete stairs with seismic joints that accommodate drift - replace with prefabricated steel stair if replacement is required.

| Cast in place concrete stair, with seismic interstory drift joint | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.021c-Carbon.html **Cost** .. raw:: html :file: C.20.11.021c-Cost.html **Energy** .. raw:: html :file: C.20.11.021c-Energy.html **Time** .. raw:: html :file: C.20.11.021c-Time.html .. raw:: html
.. raw:: html

C.20.11.021d | Monolithic cast-in-place and precast concrete stairs with no seismic joints - replace with prefabricated steel stair if replacement is required.

| Cast in place concrete stair, no seismic interstory drift joint | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.021d-Carbon.html **Cost** .. raw:: html :file: C.20.11.021d-Cost.html **Energy** .. raw:: html :file: C.20.11.021d-Energy.html **Time** .. raw:: html :file: C.20.11.021d-Time.html .. raw:: html
.. raw:: html

C.20.11.031a | Hybrid stair assembly with steel stringers and concrete treads and landings with seismic joints that accommodate drift.

| Stair consists of steel stringers with precast treads rigidly linked to stringer | Construction Quality: Normal | Seismic Installation Conditions: All | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.031a-Carbon.html **Cost** .. raw:: html :file: C.20.11.031a-Cost.html **Energy** .. raw:: html :file: C.20.11.031a-Energy.html **Time** .. raw:: html :file: C.20.11.031a-Time.html .. raw:: html
.. raw:: html

C.20.11.031b | Hybrid stair assembly with steel stringers and concrete treads and landings with no seismic joints.

| Stair consists of steel stringers with precast treads rigidly linked to stringer | Construction Quality: Normal | Seismic Installation Conditions: All Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: C.20.11.031b-Carbon.html **Cost** .. raw:: html :file: C.20.11.031b-Cost.html **Energy** .. raw:: html :file: C.20.11.031b-Energy.html **Time** .. raw:: html :file: C.20.11.031b-Time.html .. raw:: html