.. _lbl-dldb_damage_FEMA_P58_2nd_D_30_31 **************************************************** D.30.31 - Cooling Generating Systems - Chilled Water **************************************************** The following models are available: .. raw:: html

D.30.31.011a | Chiller - Capacity: < 100 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.011a-Carbon.html **Cost** .. raw:: html :file: D.30.31.011a-Cost.html **Energy** .. raw:: html :file: D.30.31.011a-Energy.html **Time** .. raw:: html :file: D.30.31.011a-Time.html .. raw:: html
.. raw:: html

D.30.31.011b | Chiller - Capacity: 100 to <350 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.011b-Carbon.html **Cost** .. raw:: html :file: D.30.31.011b-Cost.html **Energy** .. raw:: html :file: D.30.31.011b-Energy.html **Time** .. raw:: html :file: D.30.31.011b-Time.html .. raw:: html
.. raw:: html

D.30.31.011c | Chiller - Capacity: 350 to <750 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.011c-Carbon.html **Cost** .. raw:: html :file: D.30.31.011c-Cost.html **Energy** .. raw:: html :file: D.30.31.011c-Energy.html **Time** .. raw:: html :file: D.30.31.011c-Time.html .. raw:: html
.. raw:: html

D.30.31.011d | Chiller - Capacity: 750 to <1000 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.011d-Carbon.html **Cost** .. raw:: html :file: D.30.31.011d-Cost.html **Energy** .. raw:: html :file: D.30.31.011d-Energy.html **Time** .. raw:: html :file: D.30.31.011d-Time.html .. raw:: html
.. raw:: html

D.30.31.012a | Chiller - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012a-Carbon.html **Cost** .. raw:: html :file: D.30.31.012a-Cost.html **Energy** .. raw:: html :file: D.30.31.012a-Energy.html **Time** .. raw:: html :file: D.30.31.012a-Time.html .. raw:: html
.. raw:: html

D.30.31.012b | Chiller - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012b-Carbon.html **Cost** .. raw:: html :file: D.30.31.012b-Cost.html **Energy** .. raw:: html :file: D.30.31.012b-Energy.html **Time** .. raw:: html :file: D.30.31.012b-Time.html .. raw:: html
.. raw:: html

D.30.31.012c | Chiller - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012c-Carbon.html **Cost** .. raw:: html :file: D.30.31.012c-Cost.html **Energy** .. raw:: html :file: D.30.31.012c-Energy.html **Time** .. raw:: html :file: D.30.31.012c-Time.html .. raw:: html
.. raw:: html

D.30.31.012d | Chiller - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012d-Carbon.html **Cost** .. raw:: html :file: D.30.31.012d-Cost.html **Energy** .. raw:: html :file: D.30.31.012d-Energy.html **Time** .. raw:: html :file: D.30.31.012d-Time.html .. raw:: html
.. raw:: html

D.30.31.012e | Chiller - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012e-Carbon.html **Cost** .. raw:: html :file: D.30.31.012e-Cost.html **Energy** .. raw:: html :file: D.30.31.012e-Energy.html **Time** .. raw:: html :file: D.30.31.012e-Time.html .. raw:: html
.. raw:: html

D.30.31.012f | Chiller - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012f-Carbon.html **Cost** .. raw:: html :file: D.30.31.012f-Cost.html **Energy** .. raw:: html :file: D.30.31.012f-Energy.html **Time** .. raw:: html :file: D.30.31.012f-Time.html .. raw:: html
.. raw:: html

D.30.31.012g | Chiller - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012g-Carbon.html **Cost** .. raw:: html :file: D.30.31.012g-Cost.html **Energy** .. raw:: html :file: D.30.31.012g-Energy.html **Time** .. raw:: html :file: D.30.31.012g-Time.html .. raw:: html
.. raw:: html

D.30.31.012h | Chiller - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012h-Carbon.html **Cost** .. raw:: html :file: D.30.31.012h-Cost.html **Energy** .. raw:: html :file: D.30.31.012h-Energy.html **Time** .. raw:: html :file: D.30.31.012h-Time.html .. raw:: html
.. raw:: html

D.30.31.012i | Chiller - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012i-Carbon.html **Cost** .. raw:: html :file: D.30.31.012i-Cost.html **Energy** .. raw:: html :file: D.30.31.012i-Energy.html **Time** .. raw:: html :file: D.30.31.012i-Time.html .. raw:: html
.. raw:: html

D.30.31.012j | Chiller - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012j-Carbon.html **Cost** .. raw:: html :file: D.30.31.012j-Cost.html **Energy** .. raw:: html :file: D.30.31.012j-Energy.html **Time** .. raw:: html :file: D.30.31.012j-Time.html .. raw:: html
.. raw:: html

D.30.31.012k | Chiller - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012k-Carbon.html **Cost** .. raw:: html :file: D.30.31.012k-Cost.html **Energy** .. raw:: html :file: D.30.31.012k-Energy.html **Time** .. raw:: html :file: D.30.31.012k-Time.html .. raw:: html
.. raw:: html

D.30.31.012l | Chiller - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.012l-Carbon.html **Cost** .. raw:: html :file: D.30.31.012l-Cost.html **Energy** .. raw:: html :file: D.30.31.012l-Energy.html **Time** .. raw:: html :file: D.30.31.012l-Time.html .. raw:: html
.. raw:: html

D.30.31.013a | Chiller - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013a-Carbon.html **Cost** .. raw:: html :file: D.30.31.013a-Cost.html **Energy** .. raw:: html :file: D.30.31.013a-Energy.html **Time** .. raw:: html :file: D.30.31.013a-Time.html .. raw:: html
.. raw:: html

D.30.31.013b | Chiller - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013b-Carbon.html **Cost** .. raw:: html :file: D.30.31.013b-Cost.html **Energy** .. raw:: html :file: D.30.31.013b-Energy.html **Time** .. raw:: html :file: D.30.31.013b-Time.html .. raw:: html
.. raw:: html

D.30.31.013c | Chiller - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013c-Carbon.html **Cost** .. raw:: html :file: D.30.31.013c-Cost.html **Energy** .. raw:: html :file: D.30.31.013c-Energy.html **Time** .. raw:: html :file: D.30.31.013c-Time.html .. raw:: html
.. raw:: html

D.30.31.013d | Chiller - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013d-Carbon.html **Cost** .. raw:: html :file: D.30.31.013d-Cost.html **Energy** .. raw:: html :file: D.30.31.013d-Energy.html **Time** .. raw:: html :file: D.30.31.013d-Time.html .. raw:: html
.. raw:: html

D.30.31.013e | Chiller - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013e-Carbon.html **Cost** .. raw:: html :file: D.30.31.013e-Cost.html **Energy** .. raw:: html :file: D.30.31.013e-Energy.html **Time** .. raw:: html :file: D.30.31.013e-Time.html .. raw:: html
.. raw:: html

D.30.31.013f | Chiller - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013f-Carbon.html **Cost** .. raw:: html :file: D.30.31.013f-Cost.html **Energy** .. raw:: html :file: D.30.31.013f-Energy.html **Time** .. raw:: html :file: D.30.31.013f-Time.html .. raw:: html
.. raw:: html

D.30.31.013g | Chiller - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013g-Carbon.html **Cost** .. raw:: html :file: D.30.31.013g-Cost.html **Energy** .. raw:: html :file: D.30.31.013g-Energy.html **Time** .. raw:: html :file: D.30.31.013g-Time.html .. raw:: html
.. raw:: html

D.30.31.013h | Chiller - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013h-Carbon.html **Cost** .. raw:: html :file: D.30.31.013h-Cost.html **Energy** .. raw:: html :file: D.30.31.013h-Energy.html **Time** .. raw:: html :file: D.30.31.013h-Time.html .. raw:: html
.. raw:: html

D.30.31.013i | Chiller - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013i-Carbon.html **Cost** .. raw:: html :file: D.30.31.013i-Cost.html **Energy** .. raw:: html :file: D.30.31.013i-Energy.html **Time** .. raw:: html :file: D.30.31.013i-Time.html .. raw:: html
.. raw:: html

D.30.31.013j | Chiller - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013j-Carbon.html **Cost** .. raw:: html :file: D.30.31.013j-Cost.html **Energy** .. raw:: html :file: D.30.31.013j-Energy.html **Time** .. raw:: html :file: D.30.31.013j-Time.html .. raw:: html
.. raw:: html

D.30.31.013k | Chiller - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013k-Carbon.html **Cost** .. raw:: html :file: D.30.31.013k-Cost.html **Energy** .. raw:: html :file: D.30.31.013k-Energy.html **Time** .. raw:: html :file: D.30.31.013k-Time.html .. raw:: html
.. raw:: html

D.30.31.013l | Chiller - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.013l-Carbon.html **Cost** .. raw:: html :file: D.30.31.013l-Cost.html **Energy** .. raw:: html :file: D.30.31.013l-Energy.html **Time** .. raw:: html :file: D.30.31.013l-Time.html .. raw:: html
.. raw:: html

D.30.31.021a | Cooling Tower - Capacity: < 100 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.021a-Carbon.html **Cost** .. raw:: html :file: D.30.31.021a-Cost.html **Energy** .. raw:: html :file: D.30.31.021a-Energy.html **Time** .. raw:: html :file: D.30.31.021a-Time.html .. raw:: html
.. raw:: html

D.30.31.021b | Cooling Tower - Capacity: 100 to <350 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.021b-Carbon.html **Cost** .. raw:: html :file: D.30.31.021b-Cost.html **Energy** .. raw:: html :file: D.30.31.021b-Energy.html **Time** .. raw:: html :file: D.30.31.021b-Time.html .. raw:: html
.. raw:: html

D.30.31.021c | Cooling Tower - Capacity: 350 to <750 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.021c-Carbon.html **Cost** .. raw:: html :file: D.30.31.021c-Cost.html **Energy** .. raw:: html :file: D.30.31.021c-Energy.html **Time** .. raw:: html :file: D.30.31.021c-Time.html .. raw:: html
.. raw:: html

D.30.31.021d | Cooling Tower - Capacity: 750 to <1000 Ton - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.021d-Carbon.html **Cost** .. raw:: html :file: D.30.31.021d-Cost.html **Energy** .. raw:: html :file: D.30.31.021d-Energy.html **Time** .. raw:: html :file: D.30.31.021d-Time.html .. raw:: html
.. raw:: html

D.30.31.022a | Cooling Tower - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022a-Carbon.html **Cost** .. raw:: html :file: D.30.31.022a-Cost.html **Energy** .. raw:: html :file: D.30.31.022a-Energy.html **Time** .. raw:: html :file: D.30.31.022a-Time.html .. raw:: html
.. raw:: html

D.30.31.022b | Cooling Tower - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022b-Carbon.html **Cost** .. raw:: html :file: D.30.31.022b-Cost.html **Energy** .. raw:: html :file: D.30.31.022b-Energy.html **Time** .. raw:: html :file: D.30.31.022b-Time.html .. raw:: html
.. raw:: html

D.30.31.022c | Cooling Tower - Capacity: < 100 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022c-Carbon.html **Cost** .. raw:: html :file: D.30.31.022c-Cost.html **Energy** .. raw:: html :file: D.30.31.022c-Energy.html **Time** .. raw:: html :file: D.30.31.022c-Time.html .. raw:: html
.. raw:: html

D.30.31.022d | Cooling Tower - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022d-Carbon.html **Cost** .. raw:: html :file: D.30.31.022d-Cost.html **Energy** .. raw:: html :file: D.30.31.022d-Energy.html **Time** .. raw:: html :file: D.30.31.022d-Time.html .. raw:: html
.. raw:: html

D.30.31.022e | Cooling Tower - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022e-Carbon.html **Cost** .. raw:: html :file: D.30.31.022e-Cost.html **Energy** .. raw:: html :file: D.30.31.022e-Energy.html **Time** .. raw:: html :file: D.30.31.022e-Time.html .. raw:: html
.. raw:: html

D.30.31.022f | Cooling Tower - Capacity: 100 to <350 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022f-Carbon.html **Cost** .. raw:: html :file: D.30.31.022f-Cost.html **Energy** .. raw:: html :file: D.30.31.022f-Energy.html **Time** .. raw:: html :file: D.30.31.022f-Time.html .. raw:: html
.. raw:: html

D.30.31.022g | Cooling Tower - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022g-Carbon.html **Cost** .. raw:: html :file: D.30.31.022g-Cost.html **Energy** .. raw:: html :file: D.30.31.022g-Energy.html **Time** .. raw:: html :file: D.30.31.022g-Time.html .. raw:: html
.. raw:: html

D.30.31.022h | Cooling Tower - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022h-Carbon.html **Cost** .. raw:: html :file: D.30.31.022h-Cost.html **Energy** .. raw:: html :file: D.30.31.022h-Energy.html **Time** .. raw:: html :file: D.30.31.022h-Time.html .. raw:: html
.. raw:: html

D.30.31.022i | Cooling Tower - Capacity: 350 to <750 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022i-Carbon.html **Cost** .. raw:: html :file: D.30.31.022i-Cost.html **Energy** .. raw:: html :file: D.30.31.022i-Energy.html **Time** .. raw:: html :file: D.30.31.022i-Time.html .. raw:: html
.. raw:: html

D.30.31.022j | Cooling Tower - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Anchorage fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022j-Carbon.html **Cost** .. raw:: html :file: D.30.31.022j-Cost.html **Energy** .. raw:: html :file: D.30.31.022j-Energy.html **Time** .. raw:: html :file: D.30.31.022j-Time.html .. raw:: html
.. raw:: html

D.30.31.022k | Cooling Tower - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022k-Carbon.html **Cost** .. raw:: html :file: D.30.31.022k-Cost.html **Energy** .. raw:: html :file: D.30.31.022k-Energy.html **Time** .. raw:: html :file: D.30.31.022k-Time.html .. raw:: html
.. raw:: html

D.30.31.022l | Cooling Tower - Capacity: 750 to <1000 Ton - Vibration isolated equipment that is not snubbed or restrained - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Vibration isolated equipment that is not snubbed or restrained | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.022l-Carbon.html **Cost** .. raw:: html :file: D.30.31.022l-Cost.html **Energy** .. raw:: html :file: D.30.31.022l-Energy.html **Time** .. raw:: html :file: D.30.31.022l-Time.html .. raw:: html
.. raw:: html

D.30.31.023a | Cooling Tower - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023a-Carbon.html **Cost** .. raw:: html :file: D.30.31.023a-Cost.html **Energy** .. raw:: html :file: D.30.31.023a-Energy.html **Time** .. raw:: html :file: D.30.31.023a-Time.html .. raw:: html
.. raw:: html

D.30.31.023b | Cooling Tower - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023b-Carbon.html **Cost** .. raw:: html :file: D.30.31.023b-Cost.html **Energy** .. raw:: html :file: D.30.31.023b-Energy.html **Time** .. raw:: html :file: D.30.31.023b-Time.html .. raw:: html
.. raw:: html

D.30.31.023c | Cooling Tower - Capacity: < 100 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 75 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023c-Carbon.html **Cost** .. raw:: html :file: D.30.31.023c-Cost.html **Energy** .. raw:: html :file: D.30.31.023c-Energy.html **Time** .. raw:: html :file: D.30.31.023c-Time.html .. raw:: html
.. raw:: html

D.30.31.023d | Cooling Tower - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023d-Carbon.html **Cost** .. raw:: html :file: D.30.31.023d-Cost.html **Energy** .. raw:: html :file: D.30.31.023d-Energy.html **Time** .. raw:: html :file: D.30.31.023d-Time.html .. raw:: html
.. raw:: html

D.30.31.023e | Cooling Tower - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023e-Carbon.html **Cost** .. raw:: html :file: D.30.31.023e-Cost.html **Energy** .. raw:: html :file: D.30.31.023e-Energy.html **Time** .. raw:: html :file: D.30.31.023e-Time.html .. raw:: html
.. raw:: html

D.30.31.023f | Cooling Tower - Capacity: 100 to <350 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 250 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023f-Carbon.html **Cost** .. raw:: html :file: D.30.31.023f-Cost.html **Energy** .. raw:: html :file: D.30.31.023f-Energy.html **Time** .. raw:: html :file: D.30.31.023f-Time.html .. raw:: html
.. raw:: html

D.30.31.023g | Cooling Tower - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023g-Carbon.html **Cost** .. raw:: html :file: D.30.31.023g-Cost.html **Energy** .. raw:: html :file: D.30.31.023g-Energy.html **Time** .. raw:: html :file: D.30.31.023g-Time.html .. raw:: html
.. raw:: html

D.30.31.023h | Cooling Tower - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023h-Carbon.html **Cost** .. raw:: html :file: D.30.31.023h-Cost.html **Energy** .. raw:: html :file: D.30.31.023h-Energy.html **Time** .. raw:: html :file: D.30.31.023h-Time.html .. raw:: html
.. raw:: html

D.30.31.023i | Cooling Tower - Capacity: 350 to <750 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 500 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023i-Carbon.html **Cost** .. raw:: html :file: D.30.31.023i-Cost.html **Energy** .. raw:: html :file: D.30.31.023i-Energy.html **Time** .. raw:: html :file: D.30.31.023i-Time.html .. raw:: html
.. raw:: html

D.30.31.023j | Cooling Tower - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023j-Carbon.html **Cost** .. raw:: html :file: D.30.31.023j-Cost.html **Energy** .. raw:: html :file: D.30.31.023j-Energy.html **Time** .. raw:: html :file: D.30.31.023j-Time.html .. raw:: html
.. raw:: html

D.30.31.023k | Cooling Tower - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023k-Carbon.html **Cost** .. raw:: html :file: D.30.31.023k-Cost.html **Energy** .. raw:: html :file: D.30.31.023k-Energy.html **Time** .. raw:: html :file: D.30.31.023k-Time.html .. raw:: html
.. raw:: html

D.30.31.023l | Cooling Tower - Capacity: 750 to <1000 Ton - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit and is based upon 850 Ton. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.31.023l-Carbon.html **Cost** .. raw:: html :file: D.30.31.023l-Cost.html **Energy** .. raw:: html :file: D.30.31.023l-Energy.html **Time** .. raw:: html :file: D.30.31.023l-Time.html .. raw:: html