.. _lbl-dldb_damage_FEMA_P58_2nd_D_30_67 ************************************** D.30.67 - Controls and Instrumentation ************************************** The following models are available: .. raw:: html

D.30.67.011a | Control Panel - Capacity: all - Unanchored equipment that is not vibration isolated - Equipment fragility only

| Costing is per unit. | Construction Quality: Normal - Not designed for seismic loads | Seismic Installation Conditions: Unanchored equipment that is not vibration isolated Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.67.011a-Carbon.html **Cost** .. raw:: html :file: D.30.67.011a-Cost.html **Energy** .. raw:: html :file: D.30.67.011a-Energy.html **Time** .. raw:: html :file: D.30.67.011a-Time.html .. raw:: html
.. raw:: html

D.30.67.012a | Control Panel - Capacity: all - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Anchorage fragility only

| Costing is per unit. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.67.012a-Carbon.html **Cost** .. raw:: html :file: D.30.67.012a-Cost.html **Energy** .. raw:: html :file: D.30.67.012a-Energy.html **Time** .. raw:: html :file: D.30.67.012a-Time.html .. raw:: html
.. raw:: html

D.30.67.012b | Control Panel - Capacity: all - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Equipment fragility only

| Costing is per unit. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.67.012b-Carbon.html **Cost** .. raw:: html :file: D.30.67.012b-Cost.html **Energy** .. raw:: html :file: D.30.67.012b-Energy.html **Time** .. raw:: html :file: D.30.67.012b-Time.html .. raw:: html
.. raw:: html

D.30.67.012c | Control Panel - Capacity: all - Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints - Combined anchorage/isolator & equipment fragility

| Costing is per unit. | Construction Quality: Normal - Designed for seismic loads but no special seismic certification | Seismic Installation Conditions: Equipment that is either hard anchored or is vibration isolated with seismic snubbers/restraints | Notes: User to provide median demand and dispersion values. The values listed are default PACT values and do not represent the response of this component. Suggested Block Size: 1 EA The following repair consequences are available for this model: **Carbon** .. raw:: html :file: D.30.67.012c-Carbon.html **Cost** .. raw:: html :file: D.30.67.012c-Cost.html **Energy** .. raw:: html :file: D.30.67.012c-Energy.html **Time** .. raw:: html :file: D.30.67.012c-Time.html .. raw:: html