LF.PC2 - Precast Concrete Frames with Concrete Shear WallsΒΆ

The following models are available:

LF.PC2.H.HC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, High-Rise, High-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
High-Rise Building with more than 8 stories.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.H.LC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, High-Rise, Low-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
High-Rise Building with more than 8 stories.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.H.MC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, High-Rise, Moderate-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
High-Rise Building with more than 8 stories.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.H.PC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, High-Rise, Pre-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
High-Rise Building with more than 8 stories.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.L.HC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Low-Rise, High-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.L.LC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Low-Rise, Low-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.L.MC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Low-Rise, Moderate-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.L.PC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Low-Rise, Pre-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Low-Rise Building with 1-3 stories.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.M.HC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Mid-Rise, High-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.M.LC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Mid-Rise, Low-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.M.MC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Mid-Rise, Moderate-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.

Suggested Block Size: 1 EA (round up to integer quantity)


LF.PC2.M.PC | Lifeline Facilities, Precast Concrete Frames with Concrete Shear Walls, Mid-Rise, Pre-Code

Lifeline Facility damage functions are expressed in terms of an equivalent value of PGA for efficient evaluation of buildings that are components of utility and transportation systems. Only structural damage functions are developed based on PGA, since structural damage is considered the most appropriate measure of damage for utility and transportation system facilities. Median values of equivalent-PGA fragility curves are based on median values of spectral displacement of the damage state of interest and an assumed demand spectrum shape that relates spectral response to PGA. As such, median values of equivalent PGA are very sensitive to the shape assumed for the demand spectrum. Spectrum shape is influenced by earthquake source (i.e., WUS vs. CEUS attenuation functions), earthquake magnitude (e.g., large vs. small magnitude events), distance from source to site, site conditions (e.g., soil vs. rock), and effective damping, which varies based on building properties and earthquake duration (e.g., short, moderate, or long duration). These fragility curves were developed for a single set of spectrum shape factors (a reference spectrum), and a formula is provided for modifying damage state medians to approximate other spectrum shapes. The reference spectrum represents ground shaking of a large magnitude (i.e., M7.0) western United States (WUS) earthquake for soil sites (e.g., Site Class D) at site-to-source distances of 15 km or greater.
Structural System: These buildings contain floor and roof diaphragms, typically composed of precast concrete elements with or without cast-in-place concrete topping slabs. Precast concrete girders and columns support the diaphragms. The girders often bear on column corbels. Closure strips between precast floor elements and beam-column joints are usually cast-in-place concrete. Welded steel inserts are often used to interconnect precast elements. Precast or cast-in-place concrete shear walls resist lateral loads. For buildings with precast frames and concrete shear walls to perform well, the details used to connect the structural elements must have sufficient strength and displacement capacity; however, in some cases, the connection details between the precast elements have negligible ductility.
Mid-Rise Building with 4-7 stories.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.

Suggested Block Size: 1 EA (round up to integer quantity)