B.10.51 - Ordinary Reinforced Masonry WallsΒΆ
The following models are available:
B.10.51.001 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated, 4" to 6"' thick, up to 12 foot tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.002 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated, 4" to 6"' thick, greater than 12 foot tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.003 | Ordinary reinforced masonry walls with partially grouted cells, 4" to 6" thick, flexure dominated up to 12' tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.004 | Ordinary reinforced masonry walls with partially grouted cells, 4" to 6" thick, flexure dominated greater than 12' tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.011 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated, 8" to 12"' thick, up to 12 foot tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.012 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated, 8" to 12"' thick, greater than 12 foot tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.013 | Ordinary reinforced masonry walls with partially grouted cells, 8" to 12" thick, flexure dominated up to 12' tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.014 | Ordinary reinforced masonry walls with partially grouted cells, 8" to 12" thick, flexure dominated greater than 12' tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.021 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated, 16" thick, up to 12 foot tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.022 | Ordinary reinforced masonry walls with partially grouted cells, shear dominated,16"' thick, greater than 12 foot tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.023 | Ordinary reinforced masonry walls with partially grouted cells, 16" thick, flexure dominated up to 12' tall
Suggested Block Size: 100 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.10.51.024 | Ordinary reinforced masonry walls with partially grouted cells, 16" thick, flexure dominated greater than 12' tall
Suggested Block Size: 225 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time