B.20.22 - Curtain WallsΒΆ
The following models are available:
B.20.22.001 | Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Monolithic, Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.002 | Curtain Walls - Generic Midrise Stick-Built Curtain wall, Config: Insulating Glass Units (dual pane), Lamination: Unknown, Glass Type: Unknown, Details: Aspect ratio = 6:5, Other details Unknown
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.011 | Midrise stick-built curtain wall, Config: Asymmetric insulating glass units (dual-pane, unequal-thickness IGU), Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) inner AN / 1/2 in. (13 mm) outer AN LAM (0.030 PVB) IGU; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.021 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN LAM (0.030 PVB); glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.022 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN laminated, 2-sided SSG, Center Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.023 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN laminated, 2-sided SSG, Outside Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.031 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.032 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0 in. (0 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.033 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.13 in. (3 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.034 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.25 in. (6 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.035 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 2:1 sealant = dry
Suggested Block Size: 32 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.036 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 1:2 sealant = dry
Suggested Block Size: 32 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.037 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic, 2-sided SSG, Center Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.038 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic, 2-sided SSG, Outside Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.039 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.040 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 2:1 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.041 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) AN monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 1:2 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.051 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Full tempered, Details: 1/4 in. (6 mm) FT monolithic, 2-sided SSG, Center Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.052 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Full tempered, Details: 1/4 in. (6 mm) FT monolithic, 2-sided SSG, Outside Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.053 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Full tempered, Details: 1/4 in. (6 mm) FT monolithic, Seamed Edge; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.054 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Full tempered, Details: 1/4 in. (6 mm) FT monolithic, Polished Edge; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.061 | Midrise stick-built curtain wall, Config: Monolithic, Lamination: Not laminated, Glass Type: Heat strengthened, Details: 1/4 in. (6 mm) HS monolithic; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.071 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) inner AN / 1/4 in. (6 mm) outer AN LAM (0.030 PVB) IGU; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.072 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Laminated, Glass Type: Annealed, Details: 1/4 in. (6 mm) inner AN / 1/4 in. (6 mm) outer AN LAM (0.060 PVB) IGU; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.081 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Annealed, Details: 1 in. (25 mm) AN insulating glass unit (IGU) [1/4 in. (6 mm) inner and outer panes]; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.082 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Annealed, Details: 1 in. (25 mm) AN IGU [1/4 in. (6 mm) inner and outer panes]; glass-frame clearance = 0.25 in. (6 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.083 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Annealed, Details: 1 in. (25 mm) AN IGU [1/4 in. (6 mm) inner and outer panes], 2-sided SSG, Center Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.084 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Annealed, Details: 1 in. (25 mm) AN IGU [1/4 in. (6 mm) inner and outer panes], 2-sided SSG, Outside Panel; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.091 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Full tempered, Details: 1 in. (25 mm) FT IGU [1/4 in. (6 mm) inner and outer panes]; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.101 | Midrise stick-built curtain wall, Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Heat strengthened, Details: 1 in. (25 mm) HS IGU [1/4 in. (6 mm) inner and outer panes]; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = 6:5 sealant = dry
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time
B.20.22.201 | Curtain Walls - Unitized curtain wall (also generic unitized curtain wall), Config: Symmetric insulating glass units (dual-pane, equal-thickness IGU), Lamination: Not laminated, Glass Type: Full tempered, Details: 1-1/4 in. (32 mm) FT IGU [1/4 in. (6 mm) inner and outer panes], 4-sided SSG, VHBTM SGTTM; glass-frame clearance = 0.43 in. (11 mm); aspect ratio = Varies sealant = wet
Suggested Block Size: 30 SF
The following repair consequences are available for this model:
Carbon
Cost
Energy
Time